2864095

MINI MCR-SL-R-UI


MCR potiposition transducer for conversion of potentiometer positions into a standard analog signal, 0 Ω input... 100 Ω to 0 kΩ ... 100 kΩ


Price Per 1   £234.99

Routeco stock: 0
Non-Returnable Product
Please login or register for trade pricing.

Associated Products
2810272^
Phoenix Contact
£5.08
Price Per 1 Order Multiple (10)
Add to basket
Product added to basket
Routeco Stock: 0 Pricing/Availability request

2864134^
Phoenix Contact
MCR power terminal block for supplying several MINI Analog modules via the DIN rail connector, with screw connection, maximum current consumption of up to 2 A
£44.15
Price Per 1
Add to basket
Product added to basket
Routeco Stock: 0 Pricing/Availability request

2869728^
Phoenix Contact
Bus connector
£8.53
Price Per 1 Order Multiple (10)
Add to basket
Product added to basket
Routeco Stock: 0 Pricing/Availability request

^ denotes Non-Returnable Product.



Technical Specification
Construction type of deviceBuilt-in device
Depth102.5 mm
Galvanic separation between input and outputyes
Galvanic separation between inputsno
Galvanic separation between output to outputno
Galvanic separation between supply voltage and all other current circuitsyes
Height93.1 mm
Inherently safe according to EN 60947-5-6 NAMURno
IP-ratingIP20
Load500...500 Ohm
Malfunction message outputno
Mounting methodSnap mounting support rail
Number of channels1
Number of input ranges +10 V ... -10 V0
Number of input ranges +5 V ... -5 V0
Number of input ranges 0 mA ... 10 mA0
Number of input ranges 0 mA ... 20 mA0
Number of input ranges 0 mA ... 5 mA0
Number of input ranges 0 mV ... 100 mV0
Number of input ranges 0 mV ... 200 mV0
Number of input ranges 0 mV ... 300 mV0
Number of input ranges 0 mV ... 500 mV0
Number of input ranges 0 mV ... 60 mV0
Number of input ranges 0 V ... 1 V0
Number of input ranges 0 V ... 10 V0
Number of input ranges 0 V ... 2 V0
Number of input ranges 0 V ... 2.5 V0
Number of input ranges 0 V ... 20 V0
Number of input ranges 0 V ... 24 V0
Number of input ranges 0 V ... 30 V0
Number of input ranges 0 V ... 5 V0
Number of input ranges -1 V ... +1 V0
Number of input ranges 1 V ... 5 V0
Number of input ranges -10 mA ... +10 mA0
Number of input ranges -10 V ... +10 V0
Number of input ranges 10 V ... 0 V0
Number of input ranges 10 V ... 2 V0
Number of input ranges -100 mV ... +100 mV0
Number of input ranges -2 V ... +2 V0
Number of input ranges 2 V ... 10 V0
Number of input ranges -2.5 V ... +2.5 V0
Number of input ranges -20 mA ... +20 mA0
Number of input ranges 20 mA ... 0 mA0
Number of input ranges 20 mA ... 4 mA0
Number of input ranges -20 V ... +20 V0
Number of input ranges -300 mV ... +300 mV0
Number of input ranges 4 mA ... 20 mA0
Number of input ranges -5 mA ... +5 mA0
Number of input ranges -5 V ... +5 V0
Number of input ranges 5 V ... 0 V0
Number of input ranges 5 V ... 1 V0
Number of input ranges -500 mV ... +500 mV0
Number of input ranges -60 mV ... +60 mV0
Number of output ranges +10 V ... -10 V0
Number of output ranges +5 V ... -5 V0
Number of output ranges 0 mA ... 10 mA0
Number of output ranges 0 mA ... 20 mA1
Number of output ranges 0 mA ... 5 mA0
Number of output ranges 0 mV ... 100 mV0
Number of output ranges 0 mV ... 200 mV0
Number of output ranges 0 mV ... 300 mV0
Number of output ranges 0 mV ... 500 mV0
Number of output ranges 0 mV ... 60 mV0
Number of output ranges 0 V ... 1 V0
Number of output ranges 0 V ... 10 V1
Number of output ranges 0 V ... 2 V0
Number of output ranges 0 V ... 2.5 V0
Number of output ranges 0 V ... 20 V0
Number of output ranges 0 V ... 24 V0
Number of output ranges 0 V ... 30 V0
Number of output ranges 0 V ... 5 V1
Number of output ranges -1 V ... +1 V0
Number of output ranges 1 V ... 5 V1
Number of output ranges -10 mA ... +10 mA0
Number of output ranges -10 V ... +10 V0
Number of output ranges 10 V ... 0 V1
Number of output ranges 10 V ... 2 V0
Number of output ranges -100 mV ... +100 mV0
Number of output ranges -2 V ... +2 V0
Number of output ranges 2 V ... 10 V0
Number of output ranges -2.5 V ... +2.5 V0
Number of output ranges -20 mA ... +20 mA0
Number of output ranges 20 mA ... 0 mA1
Number of output ranges 20 mA ... 4 mA1
Number of output ranges -20 V ... +20 V0
Number of output ranges -300 mV ... +300 mV0
Number of output ranges 4 mA ... 20 mA1
Number of output ranges -5 mA ... +5 mA0
Number of output ranges -5 V ... +5 V0
Number of output ranges 5 V ... 0 V0
Number of output ranges 5 V ... 1 V0
Number of output ranges -500 mV ... +500 mV0
Number of output ranges -60 mV ... +60 mV0
Operation temperature-20...65 °C
Power consumption0.5 W
Rated supply voltage at DC19.2...30 V
Temperature drift0.02 %/K
Type of electric plug connectionScrew connection
Type of power supplyActive
Width6.2 mm
Features and Benefits
  • The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6.2 mm and converts potentiometer positions as a percentage to an analog standard signal. If the potentiometer range cannot be utilized to the full, an externally accessible slide switch is used to set the upper and lower potiposition end values. The output signal between 0 and 100% is based on this fixed end value.
  • The DIP switches are accessible on the side of the housing and allow the following parameters to be configured:
  • - Output signal,
  • - Automatic potentiometer detection,
  • - Open circuit detection slider and
  • - Fault evaluation type.
  • Power (19.2 V DC to 30 V DC) can be supplied through connection terminals on the modules or in conjunction with the DIN rail connector.
  • Your advantages
  • Power supply possible via the foot element (TBUS)
  • Automatic potentiometer detection without manual adjustment
  • Error indication via diagnostic LED and analog signal
  • For 100 Ω to 100 kΩ potentiometers
  • potentiometer signals to create standard signals
  • Configurable measuring range and output signals
  • Highly-compact potentiometer transducer for electrical isolation, conversion, amplification, and filtering of
  • Input and output signals can be configured via DIP switches
  • 3-way isolation
  • A potentiometer sub-range can be linearized via the "teach-in" switch on the device
Resources / Data Sheets


IMPORTANT: Please note that all product information, associated resources and links to third party websites contained within our website have been prepared solely for the purpose of providing general information only. All information is provided in good faith as a convenience to you and may be used for information purposes and guidance only and at all times in accordance with our Terms & Conditions of sale. Due to the reliance on third party data, we are unable to guarantee that the content on our sites is accurate, complete or up-to-date at any given time and it is recommended that if you are unsure if a product will fulfil all of your requirements that you always seek specialist advice from your local Routeco branch before making your selection.